'; var max=Math.min(v.length,3); if(v.length>1) v.reverse(); v.each(function(goods,index){ var vt = ($time() - goods['viewTime']); vt = Math.round(vt/(60*1000))+'分钟前浏览过:'; if(vt.toInt()>=60){ vt = Math.round(vt.toInt()/60)+'小时前浏览过:'; if(vt.toInt()>23){ vt = Math.round(vt.toInt()/24)+'天前浏览过:'; if(vt.toInt()>3){ vt = new Date(goods['viewTime']).toLocaleString()+'浏览过:'; } } }; if(!!!vt.toInt()){vt='刚才浏览了:'} goods['viewTime'] = vt; if(index

Shanghai Hengping Spectrophotometer Price List

Release date: 2014-11-08

Visible spectrophotometer

model

Price (Yuan / Taiwan)

Features and parameters

721

2600

Digital display wavelength: 335 ~ 1000nm, bandwidth 5nm

722

3600

Digital display wavelength: 335 ~ 1000nm, bandwidth 4nm

7230G

5800

Manual wavelength, wavelength 325 ~ 1100nm, large screen LCD, bandwidth 4nm

6300

Automatic wavelength, wavelength 325 ~ 1100nm, large screen LCD, bandwidth 4nm

723PC

7800

Automatic wavelength, including scanning software, wavelength 325 ~ 1100nm, large screen LCD,

Bandwidth 2nm

UV-visible spectrophotometer

752

9800

Automatic wavelength, wavelength: 200 ~ 1000nm, large screen LCD, bandwidth 4nm

754

14000

Automatic wavelength, wavelength: 190 ~ 1000nm, large screen LCD, bandwidth 4nm

756PC

19800

Automatic wavelength, including scanning software, wavelength 190 ~ 1100nm, large screen LCD,

Bandwidth 2nm

Large-screen scanning double-beam UV-visible spectrophotometer with proportional detection

V2200

7000

Wavelength range: 325-1000nm, bandwidth 2nm, high transmittance accuracy

UV2200

16000

Automatic wavelength: 190-1100nm, bandwidth 2nm, high transmittance accuracy

UV2400

18000

High resolution, low stray light, long-term stability, and high signal-to-noise ratio. Fully automatic eight-unit rack can be used for multi-sample measurement, wavelength 190 ~ 1100nm, large screen LCD, bandwidth 1.8nm

UV2600

28000

High resolution, low stray light, long-term stability, and high signal-to-noise ratio. Fully automatic eight-unit rack can be used for multi-sample measurement, wavelength 190 ~ 1100nm, large screen LCD, bandwidth 1.8nm

UV2600S

36000

High resolution, low stray light, long-term stability, and high signal-to-noise ratio. Fully automatic eight-unit rack can do multi-sample measurement, wavelength 190 ~ 1000nm, large screen LCD, bandwidth 0.5, 1, 1.8, 4nm

Large screen scanning dual-beam UV-visible spectrophotometer

UV2800

38000

Double beam, high resolution, low stray light, long-term stability, and high signal-to-noise ratio. Wavelength 190 ~ 1100nm, large screen LCD, bandwidth 1.8nm

UV2800S

46000

High resolution, low stray light, long-term stability, and high signal-to-noise ratio. Wavelength 190 ~ 1100nm, large screen LCD, bandwidth 0.5, 1, 1.8, 4nm

UV2900

68000

High resolution, low stray light, and high signal-to-noise ratio. Minimal baseline drift, high stability, wavelength 190-900nm, bandwidth 0.1, 1.2, 0.5, 1.0, 2.0, 3.0, 4.0, 5.0

Continuously adjustable

UV-Solution 2.0

4000

Workstation software for V2200 / UV2200

UV-Solution 3.0

6000

Workstation software for UV2400 / UV2600 / UV2800 / UV2800S / UV2900

Fluorescence spectrophotometer

F9300

21800

Excitation wavelength 365nm, 406nm, 480nm, 525nm, emission wavelength Em345 ~ 650nm (CT monochromator), sensitivity: quinine sulfate 1 × 10 minus 9 squares, including PC software for fluorescence data processing.

F9600

39800

The excitation light source uses high-efficiency cold light source technology. It is equipped with standard 365nm, 406nm, 480nm, 525nm, emission wavelength Em200 ~ 650nm (CT monochromator), and a formal LCD large screen display. PC can scan wavelength, scanning speed is up to 30,000nm / min, water level peak S / N ﹥ 90

F9600S

43800

Excitation light source adopts imported xenon lamp, water level Manfeng S / N ﹥ 150 excitation wavelength Ex200 ~ 750nm (standard configuration 365nm) emission wavelength Em200 ~ 800nm, can be scanned by PC, scanning speed up to 30000nm / min

F9700

88000

Ex / Em are grating-type monochromators, the wavelength is continuously adjustable, the excitation wavelength Ex: 200-900nm, bandwidth: 10nm, emission wavelength Em: 200-900nm, bandwidth 10nm, high sensitivity, water Raman peak S / N≥150 The scanning speed is increased to 48000nm / min, including fluorescence data processing software (wavelength scanning, 3D scanning, time scanning, photometry, etc.)

F9700S

108000

Ex / Em are grating-type monochromators, the wavelength is continuously adjustable, the excitation wavelength Ex: 200-900nm, the bandwidth: 2/5/10 / 20NM, four levels can be adjusted, which can meet the fluorescence analysis of many samples; the emission wavelength Em: 200 -900nm, bandwidth: 2/5/10 / 20NM four levels of adjustable, can meet the fluorescence analysis of many samples; water Raman peak S / N≥150, scanning speed is increased 48000nm / min, including fluorescence data processing software (wavelength scanning , 3D scanning, time scanning, photometry, etc.)

GC112A series gas chromatograph

GC1120-FID

6500

Hydrogen flame ionization detector

GC1120-TCD

7500

Thermal conductivity detector

GC1120-ECD

18000

Electron capture detector

GC1120-FPD

18000

Flame photometric detector

GC1120-NPD

18000

Nitrogen and phosphorus detector

GC1120 series gas chromatograph

GC1120-1

38000

Capillary injection system (including diaphragm purge, back pressure valve split) + makeup adjustment + FID

GC1120-2

38000

Dual packed column injection system + TCD

GC1120-3

38000

Dual packed column injection system + dual FID

GC1120-4

45000

Single packed column injection system + independent capillary injection system

(Including diaphragm purging and back pressure valve diverting) + makeup adjustment + double FID

GC1120-5

48000

Dual packed column injection system + independent capillary injection system

(Including diaphragm purging and back pressure valve diverting) + makeup adjustment + double FID

GC1120-6

52000

Dual independent capillary injection system (including re-ride control, diaphragm purging, back pressure valve split, independent temperature control) + dual makeup adjustment + dual FID + packed column injection accessories

(Refitted on the capillary sampler)

Liquid chromatography

LC1620A

76300

P1620A high pressure constant current pump + UV1620A ultraviolet detector + Rheodyne 7725i injection valve + intelligent reverse control workstation + C18 chromatography column

LC1620A

108300

P1620A high pressure constant current pump * 2 + UV1620A UV detector + American Rheodyne 7725i injection valve + intelligent reverse control workstation + C18 column + mixer

Electrochemical Workstation

EC6100

34000

Universal electrochemical analysis system, integrating more than ten commonly used electrochemical methods, and equipped with a variety of electrochemical accessories, providing full-service support, USB interface, universal and fast, small size, low power consumption, easy to implement with other analysis technologies Combined use

Processing......